- Very low noise
- Minimal mounting depth
- High air volume
- High reliability
- Time-saving installation and mat exchange
Unit of Measure
Specifications
Operating voltage1 | N/A AC 230 V, 50 Hz¹ |
Air volume, free blowing |
N/A 294 cfm (500 m³/h) - 1 fan |
Power consumption |
N/A 64 W |
Average noise level (DIN EN ISO 4871) |
N/A 67 db (A) |
Mounting depth |
N/A 4.2” (107 mm) |
Enclosure cut-out |
N/A 9.8 x 9.8” |
Weight (approx.) |
N/A 5.7 lbs. (2.6 kg) |
Technical Data
Axial fans, ball bearing |
N/A
service life min. 50,000 h at 77 °F (25 °C) and 65 %RH aluminum fan body, plastic rotor |
Connection |
N/A 3-pole clamp, AWG 14 (2.5 mm²), clamping torque 0.8 Nm max. |
Housing |
N/A
plastic, UL 94V-0, light grey; UV light resistant according to UL 746C (f1) |
Filter mat |
N/A G3 acc. to DIN EN 779, filtering degree 85% |
Filter material |
N/A synthetic fiber with progressive construction, temperature resistant to 212 °F, self-extinguishing class F1; moisture resistant to 100 %RH, reusable - can be cleaned by washing or vacuuming |
Operating / Storage temperature |
N/A +14 to +158 °F (-10 to +70 °C) / -40 to +158 °F (-40 to +70 °C) |
Operating / Storage humidity |
N/A max. 90 % RH (non-condensing) |
Protection class / Protection type |
N/A I (grounded) / IP32 |
Approvals |
N/A GOST TR (all), VDE (AC 230 V only); UL intended |
Important note |
N/A For reasons of pressure compensation, the roof filter fan must always be operated in combination with another filter fan (e.g. Part No. 01803.0-00) or a passive intake filter (e.g. Part No. 11803.0-00). |
- 1 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz