- For use in hazardous areas
- High switching capacity
- Compact Design
- “Pre-set” temperature
- Ready-to-use with strain relief
- Temperature class T6
                    Unit of Measure
                    
               
        
            Specifications
| Contact type (1-pole) | N/A Normally Closed (NC) | 
| Switch temperature | N/A 59 °F / 15 °C (± 5 °F /3 K tolerance) | 
| Switching Difference (Hysteresis) | N/A 9 °F ± 5 °F tolerance (5 K ± 3 K) | 
Technical Data
| Temperature class | N/A T6 | 
| Ex Protection type II 2 GD Gases | N/A Ex db IIC T6 Gb | 
| Ex Protection type II 2 GD Dusts | N/A Ex tb IIIC T85 °C Db IP66 | 
| Ambient temperature | N/A -76 to +185 °F (-60 to +85 °C) | 
| Sensor Element | N/A thermostatic bimetall | 
| Service LIfe | N/A > 100 000 cycles | 
| Max. switching capacity1 | N/A AC 250 V 10 A1 | 
| Min. switching capacity | N/A DC 1.5 V 5 mA | 
| Max. inrush current | N/A AC 16 A for 12 sec. | 
| Connection | N/A
                                                                                          silicone cable (halogen-free) 3 x AWG 18 (1.0 mm²), length 3 ft (1 m) | 
| Connection PE | N/A AWG 18 to 14 (1.0 to 2.5 mm²) | 
| Mounting | N/A
                                                                                          clip for 35 mm DIN rail, EN 60715 screw mounting M5, optional sideways mounting | 
| Housing | N/A aluminum, silver anodized | 
| Dimensions | N/A 3.7 x 1.8 x 1.9" (95 x 45 x 30 mm) | 
| Weight | N/A approx. 0.66 lbs (0.3 kg) | 
| Mounting Position | N/A variable | 
| Storage Temperature | N/A -76 to +185 °F (-60 to +85 °C) | 
| Operating / Storage humidity | N/A max. 90 % RH (non-condensing) | 
| Protection type / Protection class | N/A IP66 / I (grounded) | 
| Approvals | N/A
                                                                                          EPS 16 ATEX 1 118 X IECEx EPS 16.0054X EAC | 
- 1 currents above 4 A affect the switching difference