Unit of Measure
Specifications
Series |
N/A CSF 032, with thermostat |
Operating Voltage |
N/A AC 220-240 V, 50/60 Hz |
Heating Capacity1 | N/A 1000 W |
Max. Current |
N/A 12 A (inrush) |
Switch-Off Temperature2 | N/A 59 ºF (15 ºC) |
Switch-On Temperature3 | N/A 41 ºF (5 ºC) |
Technical Data
Heating Element |
N/A PTC resistor - temperature limiting |
Overheat Protection |
N/A built-in temperature limiter |
Surface Temperature |
N/A max. 176 ºF (80 ºC), except upper protective grille at 68 ºF (20 ºC) ambient temperature |
Air Outlet Temperature |
N/A max. 257 ºF (125 ºC), 2" (50 mm) above grill |
Axial Fan, Ball Bearing |
N/A 70,000 h at 77 ºF (25 ºC) |
Air Flow, Free Blowing |
N/A 37 cfm (63 m³/h) |
Connection |
N/A male power insert connector according to IEC320 C18 |
Housing |
N/A plastic, UL 94V-0, black |
Mounting |
N/A Clip for 35 mm DIN rail, EN 60715 |
Mounting Position |
N/A air flow directed up |
Operating Temperature |
N/A -40 to 140 ºF (-40 to 60 ºC) |
Storage Temperature |
N/A -40 to 158 ºF (-40 to 70 ºC) |
Operating/Storage Humidity |
N/A max. 90 % RH (non-condensing) |
Dimensions (H x W x D) |
N/A 6.0 x 3.5 x 2.6 inches (152.0 x 88 x 66 mm) |
Weight |
N/A approx. 16.5 oz (650 g) |
Protection Type |
N/A IP20 |
Protection Class |
N/A II (double insulated) |
Agency Approvals |
N/A UL File No. E234324, VDE, GOST TR |
- 1 At 77 °F (25 °C) ambient temperature
- 2 Tolerance of ±5 K
- 3 Tolerance of ±5 K