Unit of Measure

Specifications

Operating Voltage

N/A 120 VAC, 50/60 Hz
Heating Capacity1 N/A 250 W

Max. Current

N/A 6 A (inrush)

Pre-Fuse T (Time-Delay)

N/A 10 A
Switch-Off Temperature2 N/A 59 ºF (15 ºC)
Switch-On Temperature3 N/A 41 ºF (5 ºC)

Note

N/A Other Switch-off and Switch-on temperatures on request.

Technical Data

Heating Element

N/A PTC resistor, temperature limiting

Surface Temperature at Housing

N/A 149 ºF (65 ºC)

Overheat Protection

N/A built-in temperature limiter

Axial Fan, Ball Bearing

N/A 40,000 h at 104 ºF (40 ºC)

Axial Fan, Free Blowing

N/A 32 cfm (54 m³/h)

Connection

N/A 2-pole dual pressure clamp for solid, AWG 14 max (2.5 mm²) stranded wire (with wire end ferrule) AWG 16 max. (1.5 mm²)

Housing

N/A plastic, UL 94V-0, black

Mounting

N/A Clip for 35 mm DIN rail (EN 60 715)

Mounting Position

N/A vertical airflow (air outlet up), horizontal airflow

Dimensions (H x W x D)

N/A 4.13 x 3.35 x 4.65 inches (105 x 85 x 118 mm)

Weight

N/A 17.6 oz (500 g)

Operating Temperature

N/A -40 to 158 ºF (-40 to 70 ºC)

Storage Temperature

N/A -49 to 158 ºF (-45 to 70 ºC)

Protection Type

N/A IP20

Protection Class

N/A II (double insulated)

Agency Approvals

N/A UL File No. E150057, VDE
  • 1 At 68°F (20°C) ambient temperature
  • 2 Tolerance of ±5 K
  • 3 Tolerance of ±5 K