Important! An axial fan must be used with the HV 031 heater. Operating without a fan creates the danger of overheating.
Unit of Measure
Specifications
Power |
N/A 100 W |
Voltage |
N/A 120 VAC, 50/60 Hz |
Required Fan Size (Not Included) |
N/A 80 x 80 x 25 mm |
Min. Air Flow |
N/A 20 cfm (35 m³/h) |
Agency Approvals |
N/A UL |
Technical Data
Type |
N/A HV 031 (heater only) |
Heating Element |
N/A Resistance type cartridge heater |
Overheat Protection |
N/A built-in temperature limiter |
Heat Sink |
N/A Die-cast aluminum, glass bead finish |
Air Exit Temperature |
N/A Approx. 95 ºF (35 ºC) measured 2" (50 mm) above heater |
Connection (Heater) |
N/A 3-pole terminal, AWG 14 max. (2.5 mm2) |
Connection (Axial Fan) |
N/A 2-pole terminal (L2/N2), AWG 14 max. (2.5 mm²) |
Wiring Compartment |
N/A Plastic, UL 94V-0, black |
Mounting |
N/A Clip for 35 mm DIN rail (EN 60 715) |
Weight |
N/A 0.5 lb (240 g) |
Operating/Storage Temperature |
N/A -49 to 158 ºF (-45 to 70 ºC) |
Protection Type |
N/A IP20 |
Protection Class |
N/A I (grounded) |