Important!  An axial fan must be used with the HV 031 heater.  Operating without a fan creates the danger of overheating.
Unit of Measure

Specifications

Power

N/A 400 W

Voltage

N/A 230 VAC, 50/60 Hz

Required Fan Size (Not Included)

N/A 120 x 120 x 25 mm

Min. Air Flow

N/A 63 cfm (108 m³/h)

Agency Approvals

N/A UL, VDE

Technical Data

Type

N/A HV 031 (heater only)

Heating Element

N/A Resistance type cartridge heater

Overheat Protection

N/A built-in temperature limiter

Heat Sink

N/A Die-cast aluminum, glass bead finish

Air Exit Temperature

N/A Approx. 118 ºF (48 ºC) measured 2" (50 mm) above heater

Connection (Heater)

N/A 3-pole terminal, AWG 14 max. (2.5 mm2)

Connection (Axial Fan)

N/A 2-pole terminal (L2/N2), AWG 14 max. (2.5 mm²)

Wiring Compartment

N/A Plastic, UL 94V-0, black

Mounting

N/A Clip for 35 mm DIN rail (EN 60 715)

Weight

N/A 1.1 lb (490 g)

Operating/Storage Temperature

N/A -49 to 158 ºF (-45 to 70 ºC)

Protection Type

N/A IP20

Protection Class

N/A I (grounded)