Unit of Measure
Specifications
Setting Range |
N/A 35 to 95 % RH |
Contact Type |
N/A SPDT / Change-over |
Agency Approvals |
N/A UL |
Technical Data
Switching Difference (Hysteresis) |
N/A Approx. 4 % RH (± 3 % tolerance) - at 50 % RH |
Permissible Air Velocity |
N/A 50 ft/s (15 m/s) |
Contact Resistance |
N/A < 10 mΩ |
Service LIfe |
N/A 100,000 cycles |
Min. Switching Capacity |
N/A 100 mA at AC/DC 20 V |
Max. Switching Capacity |
N/A
5 A at AC 250 V (resistive load) DC 20 W |
EMI/EMC Compliance |
N/A EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 |
Connection |
N/A 3-pole terminal, 3 x AWG 14 max. (2.5 mm²) |
Mounting |
N/A Clip for 35 mm DIN rail (EN 60 715) |
Dimensions (H x W x D) |
N/A 2.64 x 1.97 x 1.5 inches (67 x 50 x 38 mm) |
Housing |
N/A Plastic, UL 94V-0, light gray |
Operating Temperature |
N/A 32 to 140 ºF (0 to 60 ºC) |
Storage Temperature |
N/A -4 to 176 ºF (-20 to 80 ºC) |
Protection Type |
N/A IP20 |