Unit of Measure
Technical Data
Mounting |
N/A Snap-In, mounting from outer side |
Wall Thickness |
N/A 1 to 4 mm |
Depth in Enclosure |
N/A approx. 15 mm, according to wall thickness |
Sealing |
N/A sealing gasket EPDM |
Filter |
N/A waterproof membrane |
Dimensions |
N/A Ø 70 x 33,5 mm |
Fitting Position |
N/A variable |
Note |
N/A Material adheres to limit values in accordance with RoHS3 |
Air Permeability1 | N/A 2000 l/h |
Operating/Storage Temperature |
N/A
-35 to +70 °C (-31 to +158 °F) |
Weight (Approx.) |
N/A 45 g |
Approvals |
N/A
UL E234324 EAC |
Specifications
Material |
N/A plastic according to UL94 V-0, light grey; weather proof and UV light resistant according to UL746C (f1) |
Protection Type |
N/A IP66 (EN 60529) / IPX9K (EN 40050-9) |
Packing Unit |
N/A 1 piece |
Installation
Installation |
N/A Make cut-out Ø 40+0,5 mm in enclosure wall for size M40. Attach pressure compensation element from the outer side of the enclosure (housing). Make sure that the hole is round and free of burrs. The sealing ring must be mounted on the outer side of the housing wall. Apply sufficient pressure so the five snap-in hooks fully engage. Snap-in pressure is easily adaptable to wall thickness of the enclosure. |
- 1 at a pressure difference of min. 70 mbar