FPI/FPO 018 - Filter Fan
Standard Filter Fans
Part # |
Operating Voltage |
Air Volume, Free Blowing |
Enclosure Cut-Out |
Filter Mat |
Approvals |
3D & 2D CAD |
---|---|---|---|---|---|---|
11884.0-30 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11882.0-30 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11881.0-30 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 4.88 x 4.88+0.04 inches (124 x 124+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11880.0-30 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 3.62 x 3.62+0.04 inches (92 x 92+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11874.0-00 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11873.0-00 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 8.78 x 8.78+0.04 inches (223 x 223+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11872.0-00 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11871.0-00 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 4.88 x 4.88+0.04 inches (124 x 124+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
11870.0-00 | Operating Voltage N/A | Air Volume, Free Blowing N/A | Enclosure Cut-Out N/A 3.62 x 3.62+0.04 inches (92 x 92+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01884.9-40 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 413.8 cfm (703 m3/h) | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01884.9-00 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 413.8 cfm (703 m3/h) | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01884.0-40 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 427.9 cfm (727 m3/h) | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01884.0-00 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 427.9 cfm (727 m3/h) | Enclosure Cut-Out N/A 11.46 x 11.46+0.04 inches (291 x 291+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01883.9-40 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 342.0 cfm (581 m3/h) | Enclosure Cut-Out N/A 8.78 x 8.78+0.04 inches (223 x 223+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01883.9-00 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 342.0 cfm (581 m3/h) | Enclosure Cut-Out N/A 8.78 x 8.78+0.04 inches (223 x 223+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01883.0-40 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 315.5 cfm (536 m3/h) | Enclosure Cut-Out N/A 8.78 x 8.78+0.04 inches (223 x 223+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01883.0-00 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 315.5 cfm (536 m3/h) | Enclosure Cut-Out N/A 8.78 x 8.78+0.04 inches (223 x 223+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01882.9-40 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 184.2 cfm (313 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01882.9-00 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 184.2 cfm (313 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01882.3-00 | Operating Voltage N/A DC 12 V | Air Volume, Free Blowing N/A 164 cfm (280 m3/h) | Enclosure Cut-Out N/A 6.9 x 6.9 inches (176 x 176 mm) | Filter Mat N/A none; air-flap outlet instead | Approvals N/A VDE, EAC | 3D & 2D CAD N/A |
01882.2-00 | Operating Voltage N/A DC 24 V | Air Volume, Free Blowing N/A 158.3 cfm (269 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, EAC, UL submitted | 3D & 2D CAD N/A |
01882.1-00 | Operating Voltage N/A DC 48 V | Air Volume, Free Blowing N/A 163 cfm (277 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, EAC, UL submitted | 3D & 2D CAD N/A |
01882.0-40 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 154.8 cfm (263 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01882.0-00 | Operating Voltage N/A AC 230 V, 50/60 Hz | Air Volume, Free Blowing N/A 154.8 cfm (263 m3/h) | Enclosure Cut-Out N/A 6.93 x 6.93+0.04 inches (176 x 176+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |
01881.9-40 | Operating Voltage N/A AC 115 V, 50/60 Hz | Air Volume, Free Blowing N/A 68.9 cfm (117 m3/h) | Enclosure Cut-Out N/A 4.88 x 4.88+0.04 inches (124 x 124+1 mm) | Filter Mat N/A G3 acc. to DIN EN 779, average arrestance Aa 84 % | Approvals N/A VDE, UL File No. E234324, EAC | 3D & 2D CAD N/A |